Article Text

Download PDFPDF
Do nuisance alarms decrease functionality of smoke alarms near the kitchen? Findings from a randomised controlled trial
  1. Jingzhen Yang1,2,
  2. Michael P Jones3,
  3. Gang Cheng3,
  4. Marizen Ramirez1,4,
  5. Craig Taylor1,
  6. Corinne Peek-Asa1,4
  1. 1University of Iowa, Injury Prevention Research Center, Iowa City, Iowa, USA
  2. 2The Department of Community and Behavioral Health, University of Iowa, Iowa City, Iowa, USA
  3. 3The Department of Biostatistics, University of Iowa, Iowa City, Iowa, USA
  4. 4The Department of Occupational and Environmental Health, University of Iowa, Iowa City, Iowa, USA
  1. Correspondence to Dr Jingzhen Yang, Department of Community and Behavioral Health, College of Public Health, The University of Iowa, 200 Hawkins Drive, E236 GH, Iowa City, Iowa 52242, USA; jingzhen-yang{at}uiowa.edu

Abstract

Background Many home fires begin in the kitchen. Kitchen smoke alarms are more likely to produce nuisance alarms, but few previous studies have examined the role of alarm sensor and battery types on the functionality of smoke alarms located nearest to the kitchen.

Methods Data were analysed from a 2×2 factorial randomised controlled trial conducted in rural Iowa homes (n=628). Enrolled households were randomly assigned into one of four smoke alarm/battery combinations: ionisation/zinc, ionisation/lithium, photoelectric/zinc and photoelectric/lithium. Alarm functionality was determined using a smoke test. Alarm type and battery type were compared using an intent-to-treat analysis. Logistic regression was used to identify factors that might impact the functionality of smoke alarms located nearest to the kitchen 42 months after installation.

Results Photoelectric alarms with lithium batteries had the highest rate of functionality (90.2%), whereas ionisation alarms with carbon/zinc batteries had the lowest (76.5%). Forty-two months following installation, 6.4% more of photoelectric alarms were functional than ionisation alarms, and 7.9% more of alarms with lithium batteries were functional than those with carbon/zinc batteries. Logistic regression revealed that when the indicator of nuisance alarms was included, the effect of alarm type became statistically insignificant and ionisation alarms were less likely to be functional at 42 months, partly due to increased nuisance alarms.

Conclusions Alarm type is an important consideration for certain locations. Photoelectric alarms may be more appropriate for installation nearest to the kitchen despite their increased cost. These findings can help guide consumer choices to increase protection against home fire-related injuries and deaths.

  • Fires
  • functional smoke alarm
  • home
  • kitchen location
  • nuisance alarm
  • programme
  • randomised trial
  • rural

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Funding This work was supported by the CDC/NCIPC-funded University of Iowa Injury Prevention Research Center (CDC CCR 703640) and the CDC/NIOSH-funded Great Plains Center for Agricultural Health (U07/CCU706145), both housed in the University of Iowa, College of Public Health, Department of Occupational and Environmental Health.

  • Competing interests None.

  • Patient consent Obtained.

  • Ethics approval This study was conducted with the approval of the University of Iowa.

  • Provenance and peer review Not commissioned; externally peer reviewed.